Out For Tender

Out For Tender › États-Unis › Services d'architecture, services de construction, services d'ingénierie et services d'inspection

H212-- Fire Pump Test and Alarm support

Acheteur
242-NETWORK CONTRACT OFFICE 02 (36C242), Veterans Affairs, Department of
Pays
États-Unis
Catégorie
Services d'architecture, services de construction, services d'ingénierie et services d'inspection
Date limite
Clôture dans 3 jours (3 Nov 2026 10:00 UTC-5)
Publié le
27 Oct 2026
Procédure
Sources Sought - Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)

Lire l'avis officiel et soumissionner → La soumission se fait toujours sur le portail de l'acheteur, jamais ici.

Ce que l'acheteur demande

SOURCES SOUGHT NOTICE Annual NFPA 25 Fire Pump Inspection and Performance Testing Hudson Valley VA Health Care System Castle Point Campus Notice Type: Sources Sought / Market Research This is not a solicitation. This notice is issued solely for conducting market research in accordance with FAR Part 10. The Government is seeking information from qualified vendors capable of providing annual fire pump inspection and performance testing services. Responses will be used to determine the availability of capable sources and the appropriate acquisition strategy. Contracting Activity Department of Veterans Affairs Hudson Valley VA Health Care System Place of Performance Hudson Valley VA Medical Center Castle Point Campus 41 Castle Point Road Wappingers Falls, NY 12590 Tentative NAICS and PSC NAICS: 561621, Equipment and Materials Testing Fire Control Equipment PSC: H212, Equipment and Materials Testing: Fire Control Equipment Requirement Description The Department of Veterans Affairs is conducting market research to identify qualified contractors capable of performing annual fire pump testing in accordance with the edition of NFPA 25 applicable to the facility and other applicable VA requirements. This requirement is for annual testing and inspection services only. Repairs, replacement parts, and corrective maintenance resulting from testing are not included in the contemplated contract. The contractor shall provide qualified personnel, testing equipment, labor, supervision, and documentation necessary to perform annual fire pump inspection and performance testing. Services include, but are not limited to: Visual inspection of fire pump, driver, controller, and associated equipment. Verification of pump room conditions and compliance with NFPA 25 requirements. Inspection of suction and discharge piping, valves, gauges, and relief valves. Verification of controller settings, alarms, and power supply. Churn (no-flow) testing. Full-flow performance testing at 100% and 150% rated flow, where water supply permits. Measurement and documentation of suction pressure, discharge pressure, flow, RPM, voltage, amperage, and other required performance data. Verification of pump and controller operation. Verification of supervisory and fire alarm signals affected by testing. Documentation of deficiencies, limitations, and performance results. Restoration of systems to normal operating condition following testing. Deliverables The contractor shall provide, at a minimum: Annual fire pump performance test report. Flow test data sheets and forms. Pump performance curve comparison. Inspection and test documentation. Deficiency report identifying observed impairments and recommended corrective actions. Documentation of any test limitations encountered during performance. Contractor Qualification Requirements Interested vendors should demonstrate: Experience performing annual NFPA 25 fire pump testing. Qualified personnel with documented training and experience. NICET Level II or higher in Inspection and Testing of Water-Based Systems, or equivalent qualifications, if available. Appropriate licensing, certifications, and insurance. Availability of calibrated flow and pressure testing equipment or evidence of measurement accuracy. Ability to coordinate with facility representatives and affected fire alarm monitoring/support personnel. Response Requested Interested firms shall submit the following information: Company name. UEI. CAGE Code. Business size status. Socioeconomic status (e.g., SDVOSB, VOSB, WOSB, HUBZone, Small Business, Large Business). Primary NAICS code. Capability statement (maximum five pages). Description of experience performing annual NFPA 25 fire pump testing. At least two recent projects of similar scope and complexity. Qualifications of personnel who would perform the testing. Sample annual fire pump testing report. Calibration documentation or description of testing equipment. Confirmation of ability to complete the required…

Langue de cet avis : English. Le titre et la description sont affichés tels que publiés par l'acheteur.

How this compares

  • This is one of 123 open tenders in États-Unis for Services d'architecture, services de construction, services d'ingénierie et services d'inspection.
  • Bidders were given 7 days from publication to the deadline; the median for open tenders in États-Unis is 22 days.

More open tenders from this buyer

Similar open tenders

Source: SAM · reference 36C24227Q0094 · JSON