Out For Tender › Verenigde Staten
W065--Hospital Bed Rentals Brand Name or Equal
- Aanbestedende dienst
- 257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
- Land
- Verenigde Staten
- Sluitingsdatum
- Sluit morgen (6 Nov 2026 11:00 UTC-6)
- Gepubliceerd
- 4 Nov 2026
- Procedure
- Sources Sought
Lees de officiële aankondiging en schrijf in → Inschrijven gebeurt altijd op het portaal van de aanbestedende dienst, nooit hier.
Wat de aanbestedende dienst vraagt
Special Notice Special Notice Page 4 of 4 Special Notice *= Required Field Special Notice Page 1 of 4 Network Contracting Office (NCO) - VA South Texas (VASTHCS) facilities has a requirement a contract for all labor, equipment, supervision and expertise, to provide maintenance services bed rental equipment to the VA North Texas Health Care System (VANTXHCS), 4500 South Lancaster Road, Dallas, Texas 75216, for the sole purpose of patient care for our residents and are within defined time frames for services. SALIENT CHARACTERRISTICS (Fluidair Elite) Brand Name or Equal: Adjustable Therapy Levels Dual-Mode Cooling System Integrated Scale Built-in, retractable side steps Vertically filled side rails Pause feature Hand and foot operated remote controls RENTAL EQUIPMENT SPECIFICATIONS: The following items will be delivered as needed: Rotoprone Therapy System Bed Brand name or Equal The system shall be designed to support the clinical management of patients who require automated repositioning between supine, prone, and lateral positions, including patients with respiratory conditions or other clinical indications for which prone positioning and rotational therapy have been prescribed. Provide powered, automated rotation of the patient between supine, prone, and lateral positions. Provide controlled patient positioning to support prone therapy without requiring manual turning of the patient as the sole means of achieving the position. Permit authorized clinical personnel to select, initiate, pause, and terminate positioning or rotation functions. Provide adjustable rotation parameters, including rotation angle, speed, duration, or cycle frequency, when applicable to the proposed system. Provide a means to return the patient to a safe supine or neutral position in an emergency. Permit clinical personnel to stop movement immediately through an emergency stop, stop control, or equivalent safety function. Prevent or minimize unintended rotation, positioning, or movement through appropriate controls, interlocks, alarms, or equivalent safeguards. Maintain patient support and securement throughout the complete range of intended positioning and rotation. Accommodate the patient weight, height, body dimensions, and clinical equipment identified by the Government. The proposed system shall provide a minimum patient rotation range of 62 degrees and shall accommodate a patient weight maximum of 350 pounds, unless a greater capability is offered. Fluidair Elite Therapy System Bed Brand Name or Equal The bed shall be a therapeutic support surface and bed system designed for patients requiring advanced pressure redistribution and/or air-fluidized therapy. The system shall provide therapeutic immersion and envelopment to assist in reducing pressure and shear forces. The system shall support management of the patient microclimate by assisting with moisture and heat control at the patient/support-surface interface. The system shall be appropriate for patients with complex wounds, burns, skin-graft procedures, pressure injuries, or other conditions requiring specialized therapeutic support, consistent with the manufacturer s intended use. The system shall provide a safe patient-support environment during normal operation, transfers, repositioning, treatment, and routine nursing care. The system shall accommodate patient weights maximum of 300 pounds, or the manufacturer s published safe working load, whichever is applicable. The system shall include a patient support surface with a minimum usable width of 45.28 inches and a minimum usable length of 82.6 inches, or equivalent dimensions suitable for the intended patient population. Any vendor who believes they are capable of meeting these requirements and can provide documentation demonstrating they are fully authorized by the Original Equipment Manufacturer (OEM) may submit capability information for consideration. 1.The intent of this notice is to establish sources to define the procurement…
Taal van deze aankondiging: English. Titel en beschrijving tonen we precies zoals de aanbestedende dienst ze heeft gepubliceerd.
How this compares
- Bidders were given 2 days from publication to the deadline; the median for open tenders in Verenigde Staten is 21 days.
More open tenders from this buyer
6550--Blood Bank Reagents
257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
WTX Elevator Inspections and Load Testing Services
257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
EVOLUTION HOSPITAL BEDS
257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
J065--Omnicell Service & Maintenance
257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
S207--Integrated Pest Management Services
257-NETWORK CONTRACT OFFICE 17 (36C257), Veterans Affairs, Department of
Source: SAM · reference 36C25727Q0063 · JSON