Out For Tender › Stany Zjednoczone › Usługi naprawcze i konserwacyjne
J061--Triennial Circuit Breaker and Feeder Testing
- Zamawiający
- 261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
- Kraj
- Stany Zjednoczone
- Kategoria
- Usługi naprawcze i konserwacyjne
- Termin składania ofert
- Kończy się za 6 dni (20 Nov 2026 12:00 UTC-8)
- Opublikowano
- 23 Oct 2026
- Procedura
- Solicitation
Przeczytaj oficjalne ogłoszenie i złóż ofertę → Oferty składa się zawsze na portalu zamawiającego, nigdy tutaj.
Czego szuka zamawiający
1. VAAR 852.219-75 in the solicitation has box (iii), special trade construction contractors (75 percent), marked, while the requirement is coded J061 under NAICS 238210 and FAR 52.219-14 is also included. Please confirm that the 75 percent special trade limitation in box (iii) is the limitation that applies to this award. Confirmed. This requirement is solicited under NAICS 238210. The applicable limitation on subcontracting is VAAR 852.219-75(c)(iii), 75 percent for special trade construction contractors. Offeror must comply with that limitation and submit the signed certificate. 2. The SAM.gov notice shows no set-aside, while the solicitation includes VAAR 852.219-73 (total set-aside for certified SDVOSBs). Please confirm that this requirement is a total SDVOSB set-aside. Confirmed. This is a total SDVOSB set-aside per VAAR 852.219-73 and SF1449 Block 10. NCO 21 will update the SAM.gov notice to reflect the set-aside. Offerors must be certified SDVOSB in SBA Veteran Small Business Certification at time of offer. 3. Section B.1 states that invoices are submitted upon Government inspection and acceptance. Will VA accept two invoices, one after acceptance of field testing and one after acceptance of the coordination study and final report? Yes, the VA will take two invoices. Station/contracting will review these invoices for approval. 4. Amendment 0001 added Attachment C27, Single-Line Schematics. Please confirm whether C27 and the Facility Single Line Diagram together define the full quantities to be tested (MV switches, MV cable runs and vaults, liquid-filled and dry-type transformers, circuit breakers 225A and above, and feeders), or provide an equipment list with counts. Please also identify the buildings covered by "Day 12 + TBD, new facilities since 2017." In the past, a copy of 1-line diagrams was updated with color coding of each test component and a sheet with all quantiles and locations. This should be done to ensure vendor and FMS understands what scope is. 5. For the coordination study and arc flash analysis, is the 2024 study model available to the contractor, and in what software? Is there a required software platform and CAD version for the deliverables? Yes. However, I was just informed that our 2020 circuit breaker testing is the performed format which we can provide. 6. Must the coordination study and arc flash analysis be sealed by a Professional Engineer, and if so, must the engineer be licensed in Nevada? Yes engineering seal is required. No, it does not need to be Nevada. In the past, the previous vendor has had an engineer on staff who did this. 7. Please confirm that the five years of experience in the Contractor Requirements section is verified as a responsibility matter after quotes, and that the quote itself consists of price, the signed VAAR 852.219-75 certificate, amendment acknowledgments, and the items listed in FAR 52.212-1(a). Confirmed. Contractor Requirements Para 7.3 [5-year experience] will be evaluated as part of responsibility per FAR 9.104 after quotes, not as part of technical acceptability. For quote submission, see FAR 52.212-1(a) as supplemented by Addendum: price on B.2 Schedule, signed SF1449 Block 30 if required, acknowledgment of amendments per B.1 Para 4, signed VAAR 852.219-75 certificate, and proof of SDVOSB certification status. See also 52.212-3 if not in SAM. 8. Will VA facility electricians perform switching for the outages, and will VA provide temporary power or generator support where emergency branch equipment is de-energized? It is preferred that be in the vendor s scope of work. But verbiage should state that it will be done with Electrical supervisor or designee s authority at time of switching. Vendor should be responsible for the switching of the medium voltage system (25KV). This would be the P/Q switch in Boiler plant yard, medium voltage switches, and transformers in/on the facility down stream from the P/Q switch. VA electricians may assist with switching for…
Język tego ogłoszenia: English. Tytuł i opis pokazujemy dokładnie tak, jak opublikował je zamawiający.
How this compares
- This is one of 423 open tenders in Stany Zjednoczone for Usługi naprawcze i konserwacyjne.
- Bidders were given 28 days from publication to the deadline; the median for open tenders in Stany Zjednoczone is 18 days.
More open tenders from this buyer
6515-- TruClear Hysteroscopes
261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
Q701--7 Full Time Equivalent Medical Technologists - Clinical Laboratory Scientists
261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
Q301--Specialized Medical Laboratory Testing Services, VA Palo Alto Health Care System
261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
Q701--7 Full Time Equivalent Medical Technologists - Clinical Laboratory Scientists
261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
G099--HCHV Low Demand Safe Haven Services for SFVAHCS
261-NETWORK CONTRACT OFFICE 21 (36C261), Veterans Affairs, Department of
Similar open tenders
Maintenance/Service Agreement - GE PET Discovery MI-Digital Ready System
NATIONAL INSTITUTES OF HEALTH NICHD, Health and Human Services, Department of
ANF Duchesne Bunkhouse AC Replacement
USDA-FS, CSA INTERMOUNTAIN 6, Agriculture, Department of
Maintenance, Repair, and Preservation of Edgecumbe Barge
PUGET SOUND NAVAL SHIPYARD IMF, Dept of Defense
MIDGETT #2 SSDG OVERHAUL FY27
CG-SEA-C22, Homeland Security, Department of
F108 Outer Nozzle Support Repair
FA8122 AFSC PZAAB, Dept of Defense
Source: SAM · reference 36C26127Q0067 · JSON