Out For Tender › Estados Unidos › Serviços de arquitectura, construção, engenharia e inspecção
H365--ANNUAL MEDICAL GAS TESTING POP: 12/01/2026 - 09/30/2031
- Entidade adjudicante
- 262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
- País
- Estados Unidos
- Categoria
- Serviços de arquitectura, construção, engenharia e inspecção
- Prazo
- Termina amanhã (12 Nov 2026 10:00 UTC-8)
- Publicado
- 6 Nov 2026
- Procedimento
- Combined Synopsis/Solicitation - Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
Ler o anúncio oficial e concorrer → As propostas são sempre apresentadas no portal da entidade adjudicante, nunca aqui.
O que a entidade adjudicante procura
36C26227Q0022 ******* The purpose of this amendment is to: 1. Respond to questions asked regarding this solicitation. 2. Change the Period of Performance (POP) start date from 11/20/2026 to 12/01/2026. Base: 12/01/2026 09/30/2027 OY 1: 10/01/2027 09/30/2028 OY 2: 10/01/2028 09/30/2029 OY 3: 10/01/2029 09/30/2030 OY 4: 10/01/2030 09/30/2031 3. Change the response due date from 11/09/2026 to 11/12/2026. Questions and Answers: Q. Can you please let me know the total number of outlets to be tested. A. 3,000 Total. Q. # vacuum inlets A. 3,000 Q. # of medical gas system source equipment & location Bulk Oxygen, Med air, Vacuum, Nitrogen, WAGD, Dental Air, Dental Vacuum, Carbon Dioxide. Locations Main Hospital and Building 32 (cancer center) Q. # of medical gas booms/columns A. 38, Please see attachment named BOOM INVENTORY . Q. Could you please clarify whether the prime contractor must independently hold the ASSE 6020 Medical Gas Inspector and ASSE 6030 Medical Gas Verifier certifications, or whether these requirements can be satisfied through a qualified subcontractor whose personnel possess the required certifications? A. ASSE 6020 and ASSE 6030 certifications are required. Q. What are the manufacturer, model, and serial number of the boom equipment, source equipment, vacuum and air system? At a minimum, we need a manufacturer, model #, serial number for each system and each motor/compressor. Would providing photos of the source equipment be possible? A. We do not have the serial numbers or photos of the boom equipment but please see Exell spreadsheet attached Boom Inventory which has the Make, Model and location. Q. The Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No, we cannot provide the inspection report but we are providing the boom inventory. Please see Exell spreadsheet attached Boom Inventory . Q. Can the Government provide the most recent annual medical gas inspection report, or an inventory showing quantities of outlets/inlets by gas type, zone valve boxes, area alarm panels, master alarm panels and source equipment? A. No Q. If this is a follow-on requirement, what is the prior contract number? A. Prior Contract No. : 36C26222C0020 Q. Which gases and systems are in scope (oxygen, medical air, vacuum, nitrous oxide, nitrogen, carbon dioxide, WAGD, instrument air)? A. Please refer to statement of work section V. Scope Q. Is the bulk oxygen tank owned and maintained by the gas supplier, with the contractor s scope limited to the pipeline side? A. The bulk oxygen is owned and maintained by the supplier. Q. Are Category 3 systems, such as dental air and vacuum, in scope? A. Yes Q. Does the Government expect only annual periodic inspection and testing, or a full NFPA 99 system verification each year? A. Only Annual. Q. Does each annual CLIN cover a single inspection event per year? A. Yes Q. May the ASSE 6020 and 6030 credentials be held by subcontractor personnel instead of the prime s employees? A. Certs. Must be held by the prime and subcontractor. Q. Must the field team include both a 6020 inspector and a 6030 verifier, or is credential acceptable for annual testing? A. Yes Q. Should pricing assume evening or weekend work for the ICU, OR, SICU and ED zones? A. Yes. Q. If a master alarm sensor is not on a demand check fitting, will the VA allow a brief isolation to test it, or is that test excluded? A. Yes, a brief moment. Q. Are photos required for every outlet/inlet, or only for sources, alarm panels, zone valves and deficiencies? A. Only deficiencies. Q. How many particulate and dewpoint sample points are expected, based on the number of floors in the Main Hospital and Buildings 30, 31 and 32? A. No. This test will only to be performed for installation, repair, or modification of any medical gas piping systems, Building 29, 30 has no medical…
Idioma deste anúncio: English. O título e a descrição são apresentados tal como a entidade adjudicante os publicou.
How this compares
- This is one of 127 open tenders in Estados Unidos for Serviços de arquitectura, construção, engenharia e inspecção.
- Bidders were given 6 days from publication to the deadline; the median for open tenders in Estados Unidos is 19 days.
More open tenders from this buyer
6505--FY27 Lenalidomide BPA
262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
V225--Ground Ambulance Services -BLS, ALS and CCT Service
262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
6835--Med Gas Base Plus Four
262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
J059--Tri-Annual PM & Testing of Switch Gears - Base Year
262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
W091--NMVAHCS Nitrogen Compressed Lease and Supply 2026-2031
262-NETWORK CONTRACT OFFICE 22 (36C262), Veterans Affairs, Department of
Similar open tenders
C--Martime NWR Interpretive Exhibit Services
FWS CONTRACTING ACTIVITY, Interior, Department of the
H399--Elevator Inspection Service FHCC VAMC in North Chicago IL Base 4 OY
252-NETWORK CONTRACT OFFICE 12 (36C252), Veterans Affairs, Department of
PN 110205 - SOS Hangar Renovation - Progressive-Design-Build OT
W074 ENDIST WILMINGTON, Dept of Defense
PN 110205 - SOS Hangar Renovation - Progressive-Design-Build OT
W074 ENDIST WILMINGTON, Dept of Defense
PN 110205 - SOS Hangar Renovation - Progressive-Design-Build OT
W074 ENDIST WILMINGTON, Dept of Defense
Source: SAM · reference 36C26227Q0022 · JSON