Out For Tender › Estados Unidos › Equipamento laboratorial, óptico e de precisão (exc. óculos)
Procurement of New Bench Top Single Quadrupole Inductively Coupled Plasma Mass Spectrometer (ICP-MS) System for Color Certification Program - Brand Name or Equal
- Entidade adjudicante
- FDA OFFICE OF ACQ GRANT SVCS, Health and Human Services, Department of
- País
- Estados Unidos
- Categoria
- Equipamento laboratorial, óptico e de precisão (exc. óculos)
- Prazo
- Termina hoje (24 Sep 2026 12:00 UTC-4)
- Publicado
- 21 Sep 2026
- Procedimento
- Combined Synopsis/Solicitation - No Set aside used
Ler o anúncio oficial e concorrer → As propostas são sempre apresentadas no portal da entidade adjudicante, nunca aqui.
O que a entidade adjudicante procura
Notice of Combined Synopsis/Solicitation. This is a combined synopsis/solicitation for commercial products or commercial services prepared in accordance with part 12. This announcement constitutes the only solicitation; quotes are being requested, and a separate written solicitation will not be issued. The NAICS for this requirement is: 334516. The government is not obligated to make an award. The Government is not obligated to pay costs incurred by the Contractor during quote preparation and quote submission. Background: This request is for the Division of Color Certification and Technology (DCCT), within the Office of Cosmetics and Colors, to acquire a new inductively coupled plasma mass spectrometer (ICP-MS). This system will replace an existing Agilent 7800 ICP-MS, which was purchased in May 2016 and will reach the end of its guaranteed support in October 2028. Timely replacement is necessary to ensure continuous service and to prevent any interruption in color certification activities. DCCT needs an instrument capable of determining element concentrations and accurate element ratios at low concentrations. In contrast to conventional quadrupole-based instruments, an instrument equipped with a kinetic energy discrimination-capable collision/reaction cell will provide the agency with the capability for achieving lower detection limits and higher accuracy in determining element concentrations in complex color additive and other matrices. Minimum Performance Requirements/Salient Characteristics: All of the following system requirements are minimum requirements. Equivalent requirements that differ from these minimum requirements shall be justified by the proposing vendor and evaluated by the DCCT prior to purchase. General The system shall be of a compact bench-top design to fit the space constraints of the laboratory and shall have an open architecture sample introduction area with external rotary pump(s) configured to fit under or behind the laboratory bench. The footprint for both the ICP-MS and the autosampler shall be smaller than height x width x dept: 35" x 45'' x 35. The components and/or equipment shall be new, not used or refurbished, or previously used for demonstration. The system shall be a turn-key solutionthe contractor shall be responsible for providing all hardware, components, instruments, and software that are otherwise required to meet these salient characteristics. The contractor shall provide the entire system including all necessary supplies and accessories and fittings required for immediate start-up and installation on-site at the designated laboratory delivery location. Instrument software must be able to control all components of the ICP-MS system (including autosampler, advanced diluting system, reaction system, plasma, mass analyzer, chiller, pump) with a single software program/package. The ICP-MS software shall demonstrate exceptional consistency and operational simplicity through advanced system setup and comprehensive auto-tuning of plasma operating parameters, torch alignment, collision cell conditions, ion optics (lenses), mass analyzer settings, detector parameters, and percent abundance factors all in one single step All solutions, standards, and/or consumables required to perform initial instrument qualification are the responsibility of the offeror. Single hyperbolic quadrupole for mass analysis, Agilent 7850 (G8422AA) or equal. Sample Introduction system, Agilent SPS4 (G8415A) or equal. Advanced dilution system, Agilent ADS 2 (M5172A) or equal. Operating software and shall be Microsoft Windows based software Microsoft Office modules needed for data analysis and interpretation shall be included. Color laser printer. Heat exchanger/chiller for cooling the interface. The cooling water supply to the ICP-MS mainframe shall be supplied by a non-refrigerated heat exchanger to reduce maintenance cost. Roughing pump with noise reduction (quiet) cover. Gas regulator(s). Perfluoroalkoxy alkanes…
Idioma deste anúncio: English. O título e a descrição são apresentados tal como a entidade adjudicante os publicou.
Source: SAM · reference FDA-RFQ-OC-2026-134410 · JSON