Out For Tender › Estados Unidos › Equipamento laboratorial, óptico e de precisão (exc. óculos)
Request For Quote - DART-Mass Spectrometer
This tender has closed. It stays online as a record of what was advertised.
- Entidade adjudicante
- INVESTIGATIONS AND OPERATIONS SUPPORT DALLAS, Homeland Security, Department of
- País
- Estados Unidos
- Categoria
- Equipamento laboratorial, óptico e de precisão (exc. óculos)
- Prazo
- Encerrado (23 Sep 2026 08:00 UTC-4)
- Publicado
- 14 Sep 2026
- Procedimento
- Combined Synopsis/Solicitation - No Set aside used
Ler o anúncio oficial e concorrer → As propostas são sempre apresentadas no portal da entidade adjudicante, nunca aqui.
O que a entidade adjudicante procura
Request for Quote (RFQ) 192126VHQFDL00016 DART-Mass Spectrometer 1. Point of Contact: Chris Jackson, 8222 N. Belt Line Road, Irving, Texas 75063 Questions: All questins shall be submitted no later than 1:00 pm, Eastern Time, Thursday, September 17, 2026. Email quotes to: Christopher.L.Jackson@ice.dhs.gov by 0800, Eastern, September 23, 2026. Basis for Award: The Government intends to evaluate quotes in response to this RFQ using the Lowest Price Technically Acceptable (LPTA) process. Quotes shall be evaluated in order of total price (lowest price first) until a technically acceptable quote is determined. Quotes will be evaluated for acceptability only. A quote shall be determined to be technically acceptable or unacceptable based on the rating definitions in the table below. The technically acceptable quote will then have its price evaluated for reasonableness. All quotes may not be evaluated at the Governments discretion. Rating Definitions: Acceptable The quotation meets and/or exceed the minimim specifications as listed below. Unacceptable The quotation does not meet the minimum specifications as listed below. . 2. Set Aside: None 3. NAICS: 334516 PSC: 6640 4. Description: The Government would like to purchase a Direct Analysis in Real-Time Mass Spectrometer (DART-MS) that will fulfill the HSI Forensics Laboratory mission to perform rapid, non-destructive mass spectral analyses of inks, toners, dyes, polymers, papers, adhesives, and other materials related to travel, identity, and security documents.The governments purchase would also include the following: Delivery, Setup/Installation, and Warranty Period of no-less than 1 year. The DART source must be capable of rapid qualitative and quantitative analysis with no sample preparation of a wide range of polar and nonpolar materials including polymers and polymer additives, fuel additives, drugs and metabolites (either purified or in body fluids or tissues), explosives, foods and beverages, environmental contaminants, pesticides, and chemical warfare agents. The DART system must be controlled through the software provided. The DART must be a fully integrated (with the MS and software) and be a commercially available instrument that has previously been sold and installed into US Federal and State government laboratories, industrial and pharmaceutical companies, as well as universities and colleges The DART-MS equipment must meet the following minimum requirements listed below: -TAA compliant - Must include DART JumpShot: DART JumpShot with Pulse gas flow is an easy way to complete ambient pressure desorption ionization mass spectrometry. JumpShot technology improves speed and throughput, reduces ambient background and allows for 95% helium saving over continuous flow DART. All hardware required for operation of the DART-MS instrument PC (and related peripherals that meets or exceeds the following specifications: Intel Core i5-13600 with Windows 11 Pro or Mac OSX 64-bit Operating System, Minimum of 16GB RAM, 256GB SSD & 4TB SATA disk drives, 24" flat panel monitor optical mouse, keyboard, and all necessary cables Includes accessory pumps, gas regulator(s), etc. The Mass spectrometer must meet or exceed the following specifications: Time-of-flight mass spectrometer including ESI ion source, DART ion source, isolation valve, ion transmission guide, ion accelerator, analyzer, ion detection unit, ADC system, evacuation and control system. Syringe pump for system tuning. Positive and Negative ion detection No special interface or pump required for using DART Resolving Power: greater than or equal to 10,000 (FWHM) at m/z 609 Data Acquisition Rate: up to 50Hz Mass Range of at least: m/z 7-10,000 Mass Accuracy: 3ppm (RMS) or better Supports up to multiple in-source CID voltages for a single analysis Vacuum isolation valve permits rapid pump down after venting the ion source region for maintenance Must be capable of using Helium and Nitrogen gas as a carrier gas High-Resolution,…
Idioma deste anúncio: English. O título e a descrição são apresentados tal como a entidade adjudicante os publicou.
Source: SAM · reference 192126VHQFDL00016 · JSON