Out For Tender › United States › Architectural, construction, engineering and inspection services
RFI/Sources Sought Notice, Heterotrophic Plate Count (HPC) Waterline Testing Services, Biloxi, MS, Pensacola, FL and Panama City Beach, FL
This tender has closed. It stays online as a record of what was advertised.
- Buyer
- 256-NETWORK CONTRACT OFFICE 16 (36C256), Veterans Affairs, Department of
- Country
- United States
- Category
- Architectural, construction, engineering and inspection services
- Deadline
- Closed (23 Sep 2026 10:00 UTC-5)
- Published
- 10 Sep 2026
- Procedure
- Sources Sought
Read the official notice and bid → Bidding always happens on the buyer's own portal, never here.
What the buyer is asking for
1. PURPOSE The Department of Veterans Affairs (VA) is conducting market research to identify qualified and interested firms capable of providing routine and surge Heterotrophic Plate Count (HPC) testing of potable waterlines at VA facilities along the Gulf Coast. The Government seeks capability statements from Small Businesses (including SDVOSB/VOSB) and other than small businesses, and from GSA Multiple Award Schedule (MAS) holders under SIN 541380 (Testing Laboratory Services). This RFI/Sources Sought Notice (SSN) is issued solely for information and planning purposes and does not obligate the Government to award a contract. 2. BACKGROUND & REGULATORY CONTEXT HPC (Standard Methods 9215) estimates live culturable heterotrophic microorganisms in water and is used to monitor premise plumbing microbiological condition; consistent method/media selection is essential to preserve trend comparability. Short, strict hold times for HPC samples require reliable local logistics (cooling/transport and initiation of analysis within program limitscommonly ?24 hours, and in some jurisdictions ?8 hours for compliance). In healthcare settings, CDC expects facilities to operate comprehensive water management programs; EPA notes HPC can indicate general distribution-system water quality status, and ?500 CFU/mL is used for disinfectant-residual equivalency under SWTR. 3. DRAFT SCOPE OF WORK (SUMMARY) 3.1 Methods Contractor shall perform HPC under Standard Methods (SM) 9215 using acceptable variants (e.g., 9215B, 9215D/R2A, 9215E). Contractor shall document media, incubation temperature, and duration for each sample; the selected method/media shall remain consistent throughout the period of performance for comparability of trends. 3.2 Certifications & Accreditation Contractor shall hold current state certification/accreditation explicitly listing HPC under SM 9215 for the place(s) of performance (e.g., MSDH Drinking Water Laboratory Certification in Mississippi; Florida DOH/NELAP in Florida); ISO/IEC 17025 accreditation covering HPC is preferred. Copies of certificates and scopes must be provided. 3.3 Sample Handling & Logistics Contractor shall provide sampling containers, labels, chain?of?custody (COC) forms, coolers, and transport ice/ice packs; maintain 010?°C during transport; prevent freezing. Contractor shall initiate HPC analysis within applicable program hold times and in no case exceed 24 hours from collection unless stricter state limits are applicable. 3.4 Turnaround & Reporting Standard reporting shall be provided within 48 hours of laboratory receipt. Per?sample reports must include sample ID/location, collection and receipt timestamps, method/media/incubation conditions, HPC result in CFU/mL, and QC/batch identifiers. Contractor shall flag and notify the COR for any sample exceeding 500 CFU/mL and provide interpretive notes consistent with EPA guidance. 3.5 Emergency/Surge Capability Contractor shall provide rapid response capability for urgent events (e.g., main breaks, disinfection upsets) and identify surge capacity (peak samples/day) to meet VA needs. 4. ACQUISITION PATHWAYS & MANDATORY SOURCES The Government anticipates competing this requirement via Open Market or GSA MAS SIN 541380 if available. Nothing in this RFI commits the Government to a particular path. 5. SMALL BUSINESS & VETERANS FIRST VA will consider the results of this market research to determine small business set?asides and/or the use of Veterans First authorities. SDVOSB/VOSB respondents should indicate VetCert verification status. Any decision to set aside or use VAAR Subpart 819.70 sole?source authorities (?$5M) will be made at the Governments discretion and in the best interest of the Government based on market research outcomes. 6. WHAT TO SUBMIT (Capability Statement 10 pages max) A. Firm Information: Legal name, UEI, CAGE, business size/status (SB, SDVOSB, VOSB, HUBZone, WOSB), primary NAICS (541380) and any relevant NAICS. B. MAS Information (if…
Source: SAM · reference 36C25626Q1337 · JSON